Need help?

RPV GT

Application

Filtration for air treatment centers equipped, upstream, with a pre-filter and preparatory filtration in "GTS" applications.

Application areas

  • Compact and economical
  • Large filtration surface
  • High efficiency
  • Tested for food contact according to CE 1935/2004
  • Certified inert to microbial development (ISO 846-VDI 6022)
Certificates

General Characteristics

Filtration class according to standard 29461-1 : T6-T10
Media: mini-pleated glass fiber paper
Frame: polystyrene
Lut: polyurethane
Separators: hot-melt wire
Final pressure drop: 450 Pa
Final pressure drop according to EN 13053: initial pressure drop + 100 Pa or initial pressure drop x3 (whichever is smaller).
Maximum continuous service temperature: 80°C
Relative humidity: 100%
Contact our expert
  • RPV GT

    Illustration variation
  • ePM10 70% ISO 16890 - (T6)

    • RPV65-6GT

    • Base A (mm)

      592

    • Height B (mm)

      592

    • Depth C (mm)

      292

    • Surface (m2)

      19

    • Airflow (m3/h)

      4250

    • Delta P (Pa)

      98

    • RPV65-3GT

    • Base A (mm)

      592

    • Height B (mm)

      287

    • Depth C (mm)

      292

    • Surface (m2)

      9

    • Airflow (m3/h)

      2125

    • Delta P (Pa)

      98

  • ePM1 60% ISO 16890 - (T7)

    • RPV85-6GT

    • Base A (mm)

      592

    • Height B (mm)

      592

    • Depth C (mm)

      292

    • Surface (m2)

      19

    • Airflow (m3/h)

      4250

    • Delta P (Pa)

      114

    • RPV85-3GT

    • Base A (mm)

      592

    • Height B (mm)

      287

    • Depth C (mm)

      292

    • Surface (m2)

      9

    • Airflow (m3/h)

      2125

    • Delta P (Pa)

      114

  • ePM1 60% ISO 16890 - (T8)

    • RPV95-6GT

    • Base A (mm)

      592

    • Height B (mm)

      592

    • Depth C (mm)

      292

    • Surface (m2)

      19

    • Airflow (m3/h)

      4250

    • Delta P (Pa)

      126

    • RPV95-3GT

    • Base A (mm)

      592

    • Height B (mm)

      287

    • Depth C (mm)

      292

    • Surface (m2)

      9

    • Airflow (m3/h)

      2125

    • Delta P (Pa)

      126

  • ePM1 75% ISO 16890 - (T9)

    • RPV98-6GT

    • Base A (mm)

      592

    • Height B (mm)

      592

    • Depth C (mm)

      292

    • Surface (m2)

      19

    • Airflow (m3/h)

      4250

    • Delta P (Pa)

      155

    • RPV98-3GT

    • Base A (mm)

      592

    • Height B (mm)

      287

    • Depth C (mm)

      292

    • Surface (m2)

      9

    • Airflow (m3/h)

      2125

    • Delta P (Pa)

      155

  • E10 - (T10)

    • RPV100-6GT

    • Base A (mm)

      592

    • Height B (mm)

      592

    • Depth C (mm)

      292

    • Surface (m2)

      19

    • Airflow (m3/h)

      4250

    • Delta P (Pa)

      190

    • RPV100-3GT

    • Base A (mm)

      592

    • Height B (mm)

      287

    • Depth C (mm)

      292

    • Surface (m2)

      9

    • Airflow (m3/h)

      2125

    • Delta P (Pa)

      190

* Energy consumption, kWh/year: calculated according to Eurovent Guideline 4/21-2018 | ** Energy class: according to Eurovent RS4/C/001-2019 | *** Energy class: according to Eurovent RS4/C/001-2015
Application areas

An air filtration system adapted to each sector

Illustration

Gas Turbines

An adequate air filtration solution for your gas turbines.

Discover all sectors
TFM® Service

Choose TFM® and benefit from a comprehensive maintenance contract for air filtration.

Need clean air in your workplace? With the TFM® contract, you will benefit from high-performance air filters tailored to your needs, scalable services, and dedicated teams to advise you on the installation of new equipment.

Learn more about our service

Do you have any questions? Our team is here to help.

Our experts are available to answer all your questions.

Contact our expert
Expert illustration

Hello, my name is Jürgen Alexius. What can I do for you?

Contact our expert