Need help?

FZMP SC - Glass Fiber

Application

Filtration for air treatment plants equipped with a pre-filter upstream, and in air conditioning cabinets.

Application areas

  • Compact and economical
  • Large filtration surface area
  • High efficiency
  • Tested for food contact according to CE 1935/2004
  • Certified inert to microbial growth (ISO 846-VDI 6022)
Certificates

General Characteristics

Filtration class ISO 16890 : 2016
Media: mini-pleated fiberglass paper
Frame: galvanised (G), plastic (PL), FiberPlast (F1-F2-F3-F4), Cardboard (CA)
Separators: hot-melt
Final pressure drop according to EN 13053: initial pressure drop + 100 Pa or initial pressure drop x3 (whichever is smaller).
Recommended ECO final pressure drop: 250 Pa
Maximum continuous service temperature: 70°C
Relative humidity: 100%
Contact our expert
  • FZMP SC - Glass Fiber

    Illustration variation
  • ePM10 70% ISO 16890 - (M6)

    • FZMP 65 SC

    • Base A (mm)

      592

    • Height B (mm)

      592

    • Thickness C (mm)

      47

    • Surface (m2)

      6

    • Airflow (m3/h)/Delta P (Pa)

      2000 / 42

    • Energy consumption (kWh/year)*

      >1300

    • Energy class**

      E

    • FZMP 65 SC

    • Base A (mm)

      592

    • Height B (mm)

      490

    • Thickness C (mm)

      47

    • Surface (m2)

      5

    • Airflow (m3/h)/Delta P (Pa)

      2500 / 42

    • Energy consumption (kWh/year)*

      -

    • Energy class**

      -

    • FZMP 65 SC

    • Base A (mm)

      592

    • Height B (mm)

      287

    • Thickness C (mm)

      47

    • Surface (m2)

      3

    • Airflow (m3/h)/Delta P (Pa)

      1450 / 42

    • Energy consumption (kWh/year)*

      -

    • Energy class**

      -

    • FZMP 65 SC

    • Base A (mm)

      592

    • Height B (mm)

      592

    • Thickness C (mm)

      97

    • Surface (m2)

      11

    • Airflow (m3/h)/Delta P (Pa)

      3000 / 81

    • Energy consumption (kWh/year)*

      >1300

    • Energy class**

      E

    • FZMP 65 SC

    • Base A (mm)

      592

    • Height B (mm)

      490

    • Thickness C (mm)

      97

    • Surface (m2)

      9

    • Airflow (m3/h)/Delta P (Pa)

      2500 / 81

    • Energy consumption (kWh/year)*

      -

    • Energy class**

      -

    • FZMP 65 SC

    • Base A (mm)

      592

    • Height B (mm)

      287

    • Thickness C (mm)

      97

    • Surface (m2)

      5,5

    • Airflow (m3/h)/Delta P (Pa)

      1500 / 81

    • Energy consumption (kWh/year)*

      -

    • Energy class**

      -

  • ePM1 60% ISO 16890 - (F7)

    • FZMP 85 SC

    • Base A (mm)

      592

    • Height B (mm)

      592

    • Thickness C (mm)

      47

    • Surface (m2)

      6

    • Airflow (m3/h)/Delta P (Pa)

      2000 / 69

    • Energy consumption (kWh/year)*

      >2050

    • Energy class**

      E

    • FZMP 85 SC

    • Base A (mm)

      592

    • Height B (mm)

      490

    • Thickness C (mm)

      47

    • Surface (m2)

      5

    • Airflow (m3/h)/Delta P (Pa)

      2500 / 69

    • Energy consumption (kWh/year)*

      -

    • Energy class**

      -

    • FZMP 85 SC

    • Base A (mm)

      592

    • Height B (mm)

      287

    • Thickness C (mm)

      47

    • Surface (m2)

      3

    • Airflow (m3/h)/Delta P (Pa)

      1450 / 69

    • Energy consumption (kWh/year)*

      -

    • Energy class**

      -

    • FZMP 85 SC

    • Base A (mm)

      592

    • Height B (mm)

      592

    • Thickness C (mm)

      97

    • Surface (m2)

      11

    • Airflow (m3/h)/Delta P (Pa)

      3000 / 90

    • Energy consumption (kWh/year)*

      >2050

    • Energy class**

      E

    • FZMP 85 SC

    • Base A (mm)

      592

    • Height B (mm)

      490

    • Thickness C (mm)

      97

    • Surface (m2)

      9

    • Airflow (m3/h)/Delta P (Pa)

      2450 / 90

    • Energy consumption (kWh/year)*

      -

    • Energy class**

      -

    • FZMP 85 SC

    • Base A (mm)

      592

    • Height B (mm)

      287

    • Thickness C (mm)

      97

    • Surface (m2)

      5,5

    • Airflow (m3/h)/Delta P (Pa)

      1500 / 90

    • Energy consumption (kWh/year)*

      -

    • Energy class**

      -

  • ePM1 70% ISO16890 - (F8)

    • FZMP 95 SC

    • Base A (mm)

      592

    • Height B (mm)

      592

    • Thickness C (mm)

      47

    • Surface (m2)

      6

    • Airflow (m3/h)/Delta P (Pa)

      2000 / 96

    • Energy consumption (kWh/year)*

      >2150

    • Energy class**

      E

    • FZMP 95 SC

    • Base A (mm)

      592

    • Height B (mm)

      490

    • Thickness C (mm)

      47

    • Surface (m2)

      5

    • Airflow (m3/h)/Delta P (Pa)

      2500 / 96

    • Energy consumption (kWh/year)*

      -

    • Energy class**

      -

    • FZMP 95 SC

    • Base A (mm)

      592

    • Height B (mm)

      287

    • Thickness C (mm)

      47

    • Surface (m2)

      3

    • Airflow (m3/h)/Delta P (Pa)

      1450 / 96

    • Energy consumption (kWh/year)*

      -

    • Energy class**

      -

    • FZMP 95 SC

    • Base A (mm)

      592

    • Height B (mm)

      592

    • Thickness C (mm)

      97

    • Surface (m2)

      11

    • Airflow (m3/h)/Delta P (Pa)

      3000 / 100

    • Energy consumption (kWh/year)*

      >2150

    • Energy class**

      E

    • FZMP 95 SC

    • Base A (mm)

      592

    • Height B (mm)

      490

    • Thickness C (mm)

      97

    • Surface (m2)

      9

    • Airflow (m3/h)/Delta P (Pa)

      2450 / 100

    • Energy consumption (kWh/year)*

      -

    • Energy class**

      -

    • FZMP 95 SC

    • Base A (mm)

      592

    • Height B (mm)

      287

    • Thickness C (mm)

      97

    • Surface (m2)

      5,5

    • Airflow (m3/h)/Delta P (Pa)

      1500 / 100

    • Energy consumption (kWh/year)*

      -

    • Energy class**

      -

  • ePM1 80% ISO16890 - (F9)

    • FZMP 98 SC

    • Base A (mm)

      592

    • Height B (mm)

      592

    • Thickness C (mm)

      47

    • Surface (m2)

      6

    • Airflow (m3/h)/Delta P (Pa)

      2000 / 145

    • Energy consumption (kWh/year)*

      >2400

    • Energy class**

      E

    • FZMP 98 SC

    • Base A (mm)

      592

    • Height B (mm)

      490

    • Thickness C (mm)

      47

    • Surface (m2)

      5

    • Airflow (m3/h)/Delta P (Pa)

      2000 / 145

    • Energy consumption (kWh/year)*

      -

    • Energy class**

      -

    • FZMP 98 SC

    • Base A (mm)

      592

    • Height B (mm)

      287

    • Thickness C (mm)

      47

    • Surface (m2)

      3

    • Airflow (m3/h)/Delta P (Pa)

      1250 / 145

    • Energy consumption (kWh/year)*

      -

    • Energy class**

      -

    • FZMP 98 SC

    • Base A (mm)

      592

    • Height B (mm)

      592

    • Thickness C (mm)

      97

    • Surface (m2)

      11

    • Airflow (m3/h)/Delta P (Pa)

      2500 / 130

    • Energy consumption (kWh/year)*

      >2400

    • Energy class**

      E

    • FZMP 98 SC

    • Base A (mm)

      592

    • Height B (mm)

      490

    • Thickness C (mm)

      97

    • Surface (m2)

      9

    • Airflow (m3/h)/Delta P (Pa)

      2000 / 130

    • Energy consumption (kWh/year)*

      -

    • Energy class**

      -

* Energy consumption, kWh/year: calculated according to Eurovent Guideline 4/21-2018 | ** Energy class: according to Eurovent RS4/C/001-2019 | *** Energy class: according to Eurovent RS4/C/001-2015
Application areas

An air filtration system adapted to each sector

Illustration

Automobile

From the production line to the road, protect your vehicles!

Discover all sectors
TFM® Service

Choose TFM® and benefit from a comprehensive maintenance contract for air filtration.

Need clean air in your workplace? With the TFM® contract, you will benefit from high-performance air filters tailored to your needs, scalable services, and dedicated teams to advise you on the installation of new equipment.

Learn more about our service

Do you have any questions? Our team is here to help.

Our experts are available to answer all your questions.

Contact our expert
Expert illustration

Hi, my name is Wannes Van Herck, how can I assist you?

Contact our expert